The most common mistake when sourcing materials for a noise problem is treating sound absorption and sound insulation as the same thing. They work on opposite principles, and choosing wrongly means spending money and still having the noise. Here is how absorption actually works and how to select for it on an industrial site.
Absorption vs insulation
| Absorption | Dissipates sound energy as heat inside the material. Porous, lightweight materials are best — glasswool, mineral wool |
| Insulation (blocking) | Stops sound passing through to the other side. Heavy, dense materials are best — plasterboard, steel sheet, concrete |
| The key difference | Absorption reduces reverberation in the room; insulation reduces sound escaping next door |
| In practice | Most sites combine the two — a heavy blocking layer plus an absorbent layer of glasswool or mineral wool |
⚠️Absorbent material alone will not reduce noise escaping to the next space. Conversely, a blocking panel alone leaves the room reverberant and can make it feel louder. Decide first whether your objective is reducing reverberation or blocking transmission.
The metric — NRC and absorption coefficient
Absorption is expressed as a coefficient from 0 to 1, where closer to 1 means better absorption. Averaged across several frequencies, this gives the NRC (Noise Reduction Coefficient), the figure most widely used to compare materials.
| NRC 0.0 | Fully reflective — glass, concrete, metal sheet (almost no absorption) |
| NRC 0.3–0.5 | Moderate — thin acoustic finishes, carpet |
| NRC 0.7–0.9 | Good — glasswool and mineral wool board at appropriate density and thickness |
| NRC above 0.9 | Excellent — a thick absorbent layer with an air gap behind it |
✅Do not read the NRC of the product alone — read it with the installation. The same material absorbs noticeably better at low frequencies with an air gap behind it than fixed tight to the wall.
Choosing density and thickness
Absorption works by sound passing between the fibers and dissipating through friction. Too open and the sound passes straight through; too dense and it reflects. Mid-range density is optimal for absorption.
- Density: glasswool at 24K–48K is widely used for absorption — very high density works against it
- Thickness: thicker is better for low-frequency noise (the deep hum of machinery)
- For low-frequency noise from machinery, fans and compressors, consider 50T or more plus an air gap
- High-frequency noise (metal friction, exhaust) responds to relatively thin sections
- Facing: a non-woven or perforated facing prevents fiber release while keeping absorption
Noise control by application
| Plant and pump rooms | Glasswool or mineral wool board on walls and ceilings with a perforated facing; use thickness for low frequencies |
| Inside HVAC ducts | Duct liner (internal absorption) — stopping fan noise reaching the occupied space |
| Generator rooms | Mineral wool (with fire performance) plus a blocking structure — absorption alone is not enough |
| Factory acoustic partitions | A composite of blocking panel (steel, plasterboard) and absorbent layer (glasswool) |
| Around hot equipment | Standard acoustic materials cannot be used — specify mineral wool or Cerakwool |
Acoustic performance by material
| Glasswool | Excellent absorption, light, economical — the standard acoustic material. Service temperature to 350°C |
| Mineral wool | Absorption plus fire performance — an advantage in generator rooms and beside fire compartments. Good heat resistance |
| Polyester acoustic material | An alternative where mineral fiber dust is a problem, though heat and fire performance are lower |
| Urethane and rubber foam | Excellent for insulation and condensation control, but weaker acoustically than fibrous materials |
| Aerogel | The best insulation, but unsuitable for acoustic purposes |
⚠️Standard acoustic finishes around hot equipment risk degradation and fire. Near exhaust ducts, flues and hot pipework, always confirm the service temperature and specify mineral wool or Cerakwool.
Selection in order
- 1) Define the objective — reducing reverberation (absorption), blocking transmission (insulation), or both
- 2) Characterise the noise — low frequency (machinery, fans) or high frequency (friction, exhaust)
- 3) Check the temperature — hot areas are limited to mineral wool and Cerakwool
- 4) Check fire requirements — whether the zone needs a non-combustible or semi-non-combustible rating
- 5) Set density and thickness — thicker for lower frequencies, using an air gap where possible
- 6) Choose the facing — non-woven or perforated to prevent fiber release
💡Tell us the noise source (type of machinery), the location (wall, ceiling, duct), the service temperature and any fire requirement, and we will recommend the density, thickness and facing. Phone: +82 10-4266-9745
Need a product quote or technical advice?
Our specialists will respond with a quotation quickly
Related Technical Guides
Technical Guide
Insulation Performance Compared — Thermal Conductivity, R-Value and Thickness
Technical Guide
The Complete Guide to Urethane Pipe Insulation (PUR/PIR) — Sizes, Uses, Selection
Technical Guide
Glasswool vs Mineral Wool vs Cerakwool — Choosing Insulation by Temperature
Technical Guide
Silica Materials — Fabrics, Felts and Ropes for Service Above 1000°C